Home ProductsFire-Resistant Cable

Shenghua Flexible Fireproof Cables: Engineering Survival in Extreme Fire Conditions

Certification
China Shanghai Shenghua Cable  (Group) Co., Ltd certification
China Shanghai Shenghua Cable  (Group) Co., Ltd certification
I'm Online Chat Now

Shenghua Flexible Fireproof Cables: Engineering Survival in Extreme Fire Conditions

Shenghua Flexible Fireproof Cables: Engineering Survival in Extreme Fire Conditions

Description

Shenghua Flexible Fireproof Cables: Engineering Survival in Extreme Fire Conditions​

In high-risk environments like subway tunnels, hospitals, or petrochemical plants, ​​traditional cables fail catastrophically during fires—melting at 300°C and emitting lethal halogens​​. The 1987 King’s Cross fire (toxic smoke killed 31 people) exposed this fatal flaw. Shenghua’s ​​Flexible Fireproof Cables​​ (0.6/1kV, 750V) redefine safety with copper-sheathed inorganic insulation, zero-halogen materials, and compliance with ​​JG/T313-2014/IEC 60702-2002​​, ensuring circuit integrity even at 1,000°C for 3 hours

 

​​Breakthrough Design: The Four-Layer Life-Saving Architecture​​

Shenghua’s cable structure is engineered for maximum resilience:

  1. ​​Stranded Copper Conductor (IEC 60228 Class 2)​​:
    • ​​15x Bend Flexibility​​: Survives vibrations in rail tunnels or seismic zones without fracture
       
  2. ​​Inorganic Insulation (Mica/Mineral-Based)​​:
    • ​​1,000°C/3h Circuit Integrity​​: Outperforms generic XLPE (fails at 250°C) and resists radiation in nuclear facilities
       
  3. ​​Copper Sheath (Integrated PE Wire)​​:
    • ​​Dual Grounding & EMI Shielding​​: Eliminates separate grounding wires, cutting installation costs by 20%
       
  4. ​​LSZH Outer Sheath​​:
    • ​​<100 ppm Toxic Gas Emission​​: Prevents hydrochloric acid formation during fires (per IEC 60754)
       

​​Critical Applications: Where Shenghua Saves Lives​​

  • ​​Public Transit Tunnels​​:
    Maintains power to emergency lighting during fires (e.g., London Underground’s post-King’s Cross LSZH mandate), with ​​>60% light transmittance​​ through smoke
     
  • ​​High-Rise Hospitals​​:
    Zero-halogen sheath prevents toxic gas buildup in stairwells during evacuations.
  • ​​Petrochemical Plants​​:
    Inorganic insulation resists oil/acid corrosion, while copper sheath withstands mechanical stress from pipe ruptures.

​​Certifications: Trusted by Global Safety Standards​​

Shenghua’s adherence to ​​JG/T313-2014​​ (China) and ​​IEC 60702-2002​​ (Global) validates:

  • ​​Flame Retardancy​​: Exceeds IEC 60332-3-22 vertical flame tests (flame spread ≤1.5m)
     
  • ​​Toxicity Control​​: Halogen-free materials pass IEC 60754-1 gas emission tests
     
  • ​​Interoperability​​: Compatible with Siemens/ABB switchgear without retrofitting.

​​Technical Superiority vs. Generic Fireproof Cables​​

​​Parameter​​ ​​Shenghua Cable​​ ​​Generic Mineral Cable​​
​​Max Operating Temp​​ 1,000°C (3h) 750°C (1h)
​​Bend Flexibility​​ 15× conductor diameter Rigid (fixed-installation only)
​​Toxicity​​ 0 halogens (LSZH sheath) ≤5% PVC residues
​​Lifespan​​ 30+ years (UV/chemical-resistant) 15–20 years

​​Why Engineers Specify Shenghua​​

  1. ​​Installation Efficiency​​:
    • Flexibility allows ​​7.5× bend radius​​, slashing labor time in tight spaces like ship engine rooms
       
  2. ​​Total Cost of Ownership​​:
    • ​​30-year lifespan​​ reduces replacements despite 15–20% higher upfront cost.
  3. ​​Eco-Safety​​:
    • Recyclable LSZH sheath aligns with EU RoHS/REACH, avoiding PFAS "forever chemicals"

Contact Details
Shanghai Shenghua Cable (Group) Co., Ltd

Contact Person: Ms. Mayling Zhao

Tel: +86 15901866124

Fax: 86-21-58179888

Send your inquiry directly to us (0 / 3000)